SDC 2002
4.3. TK Config Menu
4-55
Operating Instructions - Rev. 1 / 6.2003
Set the testpoint selector to testpoint “AIH/FPN”
- main menu “Monitoring”, submenu “Test Pnt”
Parade
Fig. 427: Main menu “Monitoring” / submenu “Test Pnt”
Set Illumination
Adjust the minimum density (white field, e.g. frame bar) of the NEG film to
100%. Use Light control!
Note!
The scanned image signal of the negative film is not inverted at testpoint
AIH/FPN, that means the frame bar produces peak white (D
min
)!
66
Fig. 428: Main menu “Film” / submenu “Matching”
Adjust Light (illumination) until the signal level on the wave form monitor does
not exceed 100 %.
If the peak signal values differ very much, film type “Intermediate Neg” may
give a better match.
Select
Testpoint
AIH / FPN
Kommentare zu diesen Handbüchern