Ignite SDC/HDC Robotic Camera Instruction Manual 109
Setting Soft Stops
Setting Soft Stops
Soft stops are software adjustable electrical limits for pan and tilt rotation.
The default soft stops for both pan and tilt are ± 178º.
If you install a prompter, you must set the tilt soft stops to ± 30º.
You may also have to change default pan/tilt soft stops to prevent the
camera and/or prompter from contacting an obstacle near the selected
mounting location.
To change the default soft stops, refer to the JSC-2300 SHOT Director
Robotics/Camera Controller Instruction Manual for procedures.
Specifications
Robotic (pan/tilt head) specifications are listed in Table 57.
Table 57. Robotics Specifications
Pan Range
± 178º
Tilt Range
± 178º
Tilt Range w/ Prompter
± 30º
Pan and Tilt Speed
90º/s
Acceleration
360º/s
Accuracy - Repeatability
30 arc seconds
(0.1” at 60’) (1.4mm at 10m)
Maximum Load Capacity
75.0 lbs. (35 kg)
Noise Rating (@ 30º/s)
<30 dBm @ 1m
Control
Ethernet (10 Base-T)
Control Distance
Unlimited
Control Outputs
4 (TTL)
Power
120/240, 50/60 Hz, 100 W
Weight
20 lbs (9 kg)